Vulcan-Hart Home Heaters Manual De Usuario

Descargar
Página de 37
 
Copyright 2005                                                                                    
14
                                
Vulcan V SERIES 
 Owner’s Manual 
Canadian Comfort Industries                                      
                                                     
6”
1”
10”
6”
1”
10”
12”
T
HROUGH
 T
HE
 W
ALL
6”
3”
10”
I
NTERIOR
 V
ERTICAL
F
REESTANDING 
I
NSTALLATION
 
 
HEATER PLACEMENT: 
 
 
 
Stove must be placed so that no combustibles are within, or can swing within (i.e. drapes doors), 
36” of the heater. 
 
 
 
 
 
If the stove is placed in a location where the ceiling height is less than 7’, it must follow the 
requirements in the section “Alcove Installation”. 
 
FLOOR PROTECTION REQUIREMENTS: 
 
 
 
Stove and floor protection must be installed on a level secure floor 
 
 
 
 
 
The stove must be installed on a non-combustible floor protector (i.e. sheet steel with cement, tile 
slate) extending the full width and depth of the stove and extending 6” in front of the stove. Floor 
protector needs to be a minimum of 24.5” deep X 30.5” wide and be a minimum of .018” thick (26 
gauge). 
 
 
 
 
 
Must extend under and 2” to each side of chimney tee (if used). 
 
 
MINIMUM CLEARANCES TO COMBUSTIBLES 
    
(Figures 12-17) 
 
  1”  From Back Of Heater to Combustibles 
  3”  From PL Vent to Combustibles 
10”  From Front Side of Heater to Combustibles 
   
  1”  From Back Corner of Heater to Combustibles 
  6” Non Combustible Surface In Front Of Heater 
16”  From Top Of Heater to Combustibles 
  36”  to drapes, doors, anything that can swing 
 
   
CLEARANCES – “STRAIGHT INSTALLATION”: 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                            Figure 12 
 
 
 
 
 
 
Figure 13