Vulcan V SERIES 
 Owner’s Manual 
Canadian Comfort Industries                                     
                                                   
O
UTSIDE 
A
IR 
 
 
 
Outside air is REQUIRED ON ALL MOBILE HOME INSTALLATIONS
 
Outside air is strongly recommended for all other installations. Failure to install intake air may result 
in improper combustion as well as the unit smoking during power failures. 
 
Metal pipe, ONLY, either solid or flexible, must be used in all outside air installations.(B)  
NOTE:  Non-metallic material MUST NOT BE USED for outside air installations. 
 
A wind shield, (C), over the termination of the outside air pipe or a 90 degree elbow or bend directed 
away from the prevailing winds MUST be used when an outside air pipe is installed through the side 
of a building.  Keep the outside air pipe termination at least 1 foot away from the exhaust system 
termination.   
 
When outside air is taken from an existing chimney the exhaust system must not terminate in the 
same chimney. 
 
The outside air pipe on your stove is 2" OD.  The outside air connecting pipe must be at least 2" ID  
The outside air connecting pipe must be as short and free of elbows as possible, and must fit over
(A), not inside, the outside air pipe on your stove.  
 
 
Through The Wall Kits Include
3
 FOOT PACKAGE 
 PART
#
  ACFAKT
03   10
 FOOT PACKAGE 
 
P
ART
#
  ACFAKT
10 
 
1 – 2”  Galvanized Hood c/w screen 
 
 
1 – 2” Galvanized Hood c/w screen 
1 – 2” Aluminum Flex Duct –  
 
 
 
1 – 2” Aluminum Flex Duct – 
compressed 15” length,  extends to 30” – 36” 
 
compressed 4’ length, extends to 120”   
2 – 2” Worm Gear Clamps 
 
 
 
2 – 2” Worm Gear Clamps   
 
NOTE: Available from your local Authorized Dealer or Dansons Group Inc.  1-877-303-3134 
 
 
 
 
 
Figure 11