IT IS CRITICAL FOR THE CORRECT OPERATION OF YOUR STOVE THAT THE BURN 
GRATE, AIR INLET DAMPER, COMBUSTION FAN SPEED, AND  
1 & 4 FUEL RATE BE SET CORRECTLY!  
 
HIGH QUALITY FIRE
 should burn with a brisk, yellow flame.  A flame exhibiting a lazy, orange or sooty 
characteristic is a poor quality and inefficient flame.  A poor flame produces less heat, increases sooting and may 
cause a smoky exhaust.  If a poor flame exists for any period of time, clean your stove and exhaust system.  
 
Note: if log option is purchased, do not install until initial setup is complete 
 
START APPLIANCE AS PER LIGHTING INSTRUCTIONS
,
  
let stove run for approx. 10 minutes before turning the stove to the # 4 setting (or High), to 
begin to make fine adjustments
.  AUGER CYCLE indicator
 should be lit “ON” for 3 seconds 
and  “OFF” for 3-5 seconds. Adjust the
 AIR INLET DAMPER
. This will have to be set, as the 
factory sends all units out with the damper wide open to accommodate a wide range of 
installations and elevations. 
 
 
AIR INLET DAMPER
:    Slide open or close 
damper as needed to obtain a fire that is brisk 
enough to carry ash out of the grate, but not so 
brisk that it carries pellets out as well (known as 
“Pop corning”). Normally you should find that the 
damper will need to be closed two-thirds to three 
quarters, but will vary with length of vent run, pellet 
quality and elevation. The best way to set this is at 
the 
FUEL SETTING
 
#4.
  
 
 
When you are pleased with the burn and how the appliance is operating,  you 
are now ready to set the board up at LOW setting.   
 
 
Set 
FUEL RATE
 to 
#1 or LOW setting
.  Again let this burn for 
approx. 10 minutes before making any adjustments. The AUGER 
CYCLE indicator should be “OFF” for approx 9 – 14 seconds 
between auger turnings (light ON). If “Pop corning” is taking place 
at this setting adjust the 
COMBUSTION FAN SPEED.
 
 
 
COMBUSTION FAN SPEED (Draft):
 In a few instances 
because of prevailing conditions pertinent to your specific 
installation, or even different batches of pellet fuel, the 
COMBUSTION FAN SPEED
 may be adjusted to increase or 
decrease the amount of air moving through the grate for the 
cleanest burn. Fan speed can be adjusted by adjusting the 
FAN
 
trim pod 
COUNTER CLOCKWISE to INCREASE 
the speed and 
CLOCKWISE to DECREASE
 the speed of the combustion fan.   
 
FUEL RATE:
 Fuel rate at the Lowest (number 1) and highest (number 4) settings can be 
changed by adjusting the 
#1 or #4 TRIM PODS 
located on the control panel.  To 
INCREASE
 fuel rate turn trimmer 
COUNTER CLOCKWISE
 and to 
LOWER
 turn 
CLOCKWISE
. To assist in knowing what changes you made, you 
should note the amount of time the light on the 
AUGER CYCLE
 stays “OFF”. (Note: The light stays “off” when ever 
the fuel feed motor is not running). Lengthening the time this light stays “OFF” lowers the fuel feed and 
shortening the “OFF” time increases the fuel feed
Factory Setting #1 light “OFF” is approx. 9-11 seconds, 
#4 light “OFF” is 3-4 seconds. 
Stove Back Panel
Right Hand
Side Panel
Air Inlet
Slide Rod
Rubber 
GrometT
FINE TUNE ADJUSTMENTS
1
4
FAN
Increase
Decrease
FEED RATE
START
FEED RATE
1
2
3