Vulcan-Hart Home Heaters Manual De Usuario

Descargar
Página de 37
 
Copyright 2005                                                                                    
21
                                
Vulcan V SERIES 
 Owner’s Manual 
Canadian Comfort Industries                                      
                                                    
 
T
HE 
C
ONTROLS   
 CONTINUED
  
 
TRIM POTS (Fine Tune Adjustments)
– Factory Settings  
 
The COMBUSTION FAN (FAN), HI (4) and LO (1) FEED RATE trim pots have been preset at the 
factory, but may need to be adjusted onsite after your installation is complete.  Due to different 
installation setups, length and size of venting, and pellet fuel quality, the preset from the factory will 
not always be correct.  These settings will accommodate virtually all wood pellet fuels.  
 
FUEL FEED 
rates at the Lowest (number 1) and highest (number 4) settings can be adjusted by 
adjusting the fine tune trim pots located on the control panel.  To raise fuel feed turn trim pot 
counter clockwise and to lower turn clockwise. To assist in knowing what the change is you 
should note the amount of time the light on the AUGER CYCLE LED stays OFF. (Note: The light 
stays on when ever the fuel feed motor, AUGER CYCLE, is running).
 Lengthening the time this 
LED stays OFF lowers the fuel feed and shortening the off-time increases the fuel feed
.  
 
COMBUSTION FAN SPEED (FAN) 
In a few instances because of prevailing conditions pertinent to your specific installation, or even 
different batches of pellet fuel, the COMBUSTION FAN SPEED may be adjusted to raise or lower 
the amount of air moving through the grate for the cleanest burn. The FAN speed can be adjusted 
by adjusting the FAN trim pot COUNTER CLOCKWISE to INCREASE
 
the speed and CLOCKWISE to DECREASE the speed 
of the combustion fan.  
 
Note: If you attempt to adjust the Fuel Feed Trim Pots, use a small precision screwdriver.  
         The Trim Pots do not make a full rotation.    
          If using a metal screwdriver, be gentle as the plastic trim pot slot can be damaged or stripped.  
 
FAN SPEED
  (Convection or heating)  
The FAN SPEED controls the speed of the room air fan.  This fan blows room air through the heat 
exchange tubes and back into the room.  The FAN SPEED has 5 different speeds, these are 
controlled by pushing the FAN SPEED touch pad. The Low LED will be solid when on the lowest fan 
speed, the LOW & MED will both be solid when the next highest speed is selected and so on. .When 
the FEED RATE is set to a higher position, the FAN SPEED should be set higher and visa versa.  
When the FEED RATE is set at [3 OR 4] set the FAN SPEED to [MED/HIGH]. If you forget, the room 
air fan's (L140) temperature limit snap switch automatically sets the fan on high when your stove is 
producing heat faster than the fan is carrying it into the room.  This may occur when the heat control 
lever is set at [3 or 4] and the FAN SPEED is set to a very low or off setting.  After the fan runs at this 
automatic high setting a few minutes, it may cycle back to its lower setting and may continue to cycle 
between [HIGH ] and your selected setting.  The circulation (room air) fan cycling
 from high to low is 
a normal condition, as well as a safety feature of your appliance. 
 
AUGER CYCLE 
The AUGER CYCLE LED indicates when a electrical signal is being sent to the auger motor.  It is 
NOT used to indicate the actual movement of the auger.  When the signal is being sent the LED will 
be solid for 3 seconds. When the LED is off no signal is being sent
.  
   
 
S
HUTTING THE STOVE 
OFF 
 
Note: DO NOT UNPLUG your stove if there is a fire going or if the stove is still active.  This could result in smoke coming back 
into the room.  Remember the EXHAUST FAN is needed to force the exhaust out of the stove. 
 
On the CCI “AcuTron” Board firmly touch the OFF touch pad.  The FUEL RATE LED will turn off.  The AUGER CYCLE LED will 
turn off.  The auger will stop feeding fuel to the fire and the FAN speed LED will flash indicating that the appliance is in the “Shut 
Down” mode.  The fire will go out and  the fans will continue to run until your stove cools down at which time the fans will 
automatically shut off and NO LED’s will remain ON. 
HI
MED
LOW
  FAN SPEED
OFF
FAN
SPEED
AUGER
CYCLE