Vulcan V SERIES 
 Owner’s Manual 
Canadian Comfort Industries                                      
                                                    
A
PPENDIX 
“C” 
Wall Thermostat 
(option)
 
    INSTALLATION 
 
NOTE:  Always Disconnect Power Before Performing the Thermostat Installation 
 
A 24 volt wall thermostat and 25 feet of 18 gage thermostat wire is included in your heaters accessory package. It is 
recommended that the thermostat and thermostat wire be installed by an authorized 
VULCAN “V” Series
 dealer. 
 
Tools Needed 
¼” Hex Nutsetter & Driver 
 
 
Wirestripper 
 
 
Smaller size Flat Head Screwdriver 
 
 
Installation Steps 
Follow the thermostat manufactures installation procedures for the Heating Thermostats 
 
1.  Unplug stove power cord from the wall outlet. 
2.  To gain access to the inside of the stove, remove the six x ¼” hex screws from the slotted back access 
panel. 
3.  Unscrew the control board from the side of the heater.  2  x ¼” hex screws. 
4.  Locate the thermostat terminal block, marked T’STAT INPUT, found on the back of the board (see figure 
31). 
5.  Be sure to run the thermostat wires through one of the slots of the rear access panel, before connecting the 
wires. 
6.  Connect the two wires from your thermostat to the terminals (one per terminal).  Ensure the wires are firmly 
connected. 
7.  Connect the two wires at your wall thermostat to their terminals.  Ensure these are firmly connected. 
8.  Remove the black two prong jumper, (see figure 32), located on the front, left hand side, near the bottom 
corner and reconnect it to only one of the posts. (see figure 33). 
9.  Reinstall the control board and the slotted rear access panels. 
10.  Plug in the stove and you are ready to operate with your thermostat! 
figure 31 
 
 
figure 32 
 
 
figure 33 
        figure 34 
IMPORTANT: IF THE WALL THERMOSTAT PROVIDED IS NOT USED, THE JUMPER IS 
REQUIRED FOR THE  STOVE TO OPERATE IN MANUAL MODE 