8.2 Electrical connections
The cables for the power connection are brought out at the front of the stator (B side). The
open cable ends must be connected in a terminal box, which must be provided by the
machine manufacturer. Sufficient installation space must be provided in the axes
construction. Standard MOTION–CONNECT cables, which are available with the standard
range of accessories for the drive system, can be used from this EMC-compliant terminal
box (minimum degree of protection: IP54).
8.2.1
Power connection
Connection assignment
Table 8- 4
Power connection for torque motor
Converter
Torque motor/stator
U2
U
V2
V
W2
W
For information on connecting the power, please also refer to the figures relating to system
integration in the section titled "System requirements". The rotor rotates clockwise if the
torque motor is connected to phase sequence U, V, W. Also refer to "Direction of rotation" in
Chapter "Technical features".
8.2.2
Signal connection
The temperature monitoring circuits must not be connected without a protection module.
DANGER
Electrical shock hazard!
The circuits of Temp–S and Temp–F do not have safety isolation with respect to the power
The circuits of Temp–S and Temp–F do not have safety isolation with respect to the power
circuits according to the specifications for safety isolation in compliance with EN 61800-5-1
(previously, safety isolation according to EN 50178 (VDE 0160)).
Connecting the temperature monitoring circuits to the SMC20 Sensor Module does not fulfill
Connecting the temperature monitoring circuits to the SMC20 Sensor Module does not fulfill
the requirements of protective separation to EN 61800-5-1. The temperature monitoring
circuits must be connected via the SME12x.