Interfaces 
 
8.2 Electrical connections 
 
The cables for the power connection are brought out at the front of the stator (B side). The 
open cable ends must be connected in a terminal box, which must be provided by the 
machine manufacturer. Sufficient installation space must be provided in the axes 
construction. Standard MOTION–CONNECT cables, which are available with the standard 
range of accessories for the drive system, can be used from this EMC-compliant terminal 
box (minimum degree of protection: IP54). 
8.2.1 
Power connection 
Connection assignment 
Table 8- 4 
Power connection for torque motor 
Converter 
Torque motor/stator 
U2 
V2 
W2 
For information on connecting the power, please also refer to the figures relating to system 
integration in the section titled "System requirements". The rotor rotates clockwise if the 
torque motor is connected to phase sequence U, V, W. Also refer to "Direction of rotation" in 
Chapter "Technical features".  
8.2.2 
Signal connection 
The temperature monitoring circuits must not be connected without a protection module. 
 
DANGER 
 
Electrical shock hazard! 
The circuits of Temp–S and Temp–F do not have safety isolation with respect to the power 
circuits according to the specifications for safety isolation in compliance with EN 61800-5-1 
(previously, safety isolation according to EN 50178 (VDE 0160)). 
Connecting the temperature monitoring circuits to the SMC20 Sensor Module does not fulfill 
the requirements of protective separation to EN 61800-5-1. The temperature monitoring 
circuits must be connected via the SME12x. 
 
 
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 
143