OUTSTATION 
3.1 SPECIFICATION 
3.1.1  Mains voltage ranges 
The Outstation will work over: 
 
  
 
85 – 264 V RMS 
 
Note the power supply used is auto-ranging over the above voltage range. 
 
3.1.2  Mains frequency range 
All TC12 equipment will work from 47 Hz to 63 Hz. 
 
3.1.3 Mains cu
OTU rack including four Detector cards 
 
 250 mA at 240 V 
 
3.1.4  Temperatu
The OTU will work over  
 
 
 
-15 
°C to 75 °C. 
 
Humidity: 
 
     96% 
at 
40 
°C non-condensing 
 
3.1.5  Size and Weight 
Size: 
 
Height 
     222.3 
mm 
 
Width 
     482.6 
mm 
 
Depth 
     305.0 
mm 
 
Weight 
     5.4 
Kg 
 
NOTE: The weight of the OTU does not include detectors or their backplanes. 
 
.1.6  Detector Power Supply 
The standard OTU PSU can supply 750 mA @ 24 V for detectors. 
 
If a double OTU is fitted the 24 V supply for detectors is limited to 400 mA. 
 
3.2 INSTALLATION 
3.2.1 General 
Installation and commissioning of the Outstation is carried out in the following 
order: 
  - Configure the Outstation PCB via PCB switches 
  - Install the mechanical assembly 