[AUTO] AutoWave
This  revolutionary  new  process  automatically 
computes the best MultiWave II setting for a par-
ticular power load as presented by the connected 
equipment. The beauty of this system is its ability 
to  instantly  change  the  power  setting  of  the AC 
regenerator with the dynamic load variations the 
equipment presents.
AutoWave  automatically  selects  MultiWave™  2-
4 depending on the dynamics of the power load. 
The selection is made continuously as the power 
factor changes.
Music  is  a  dynamic  medium  as  is  video.  One 
MultiWave  II  setting  may  be  the  best  when  an 
audio/video system is reproducing low level infor-
mation and another MultiWave II setting may be 
better when higher levels of power are delivered 
to either the loudspeaker or to a video monitor.
AutoWave  solves  this  problem  by  selecting  the 
exact waveform combination based on the equip-
ment’s dynamic needs.
Notice of MultiWave II operation:
Any  turntable  or  equipment  with  AC  synchronous  fans 
should not be used with MultiWave II or AutoWave. These 
products must be used with 60Hz SINE mode or be plugged 
into the Filtered AC outlets.
Servo System
The Power Plant P1000 provides a virtual Servo 
System  to  continually  correct  for  any  DC  offset. 
This will reduce hum from problematic or sensitive 
transformers  as  the  Power  Plant  produces  pure 
AC  waveforms  indefinitely  without  the  need  for 
calibration. 
Troubleshooting Guide
The Power Plant P1000 sets a new mark for per-
formance  and  protection.  It  has  been  designed 
to  bring  forth  the  absolute  best  from  the  con-
nected  equipment.  In  addition  to  the  audio  and 
video improvements, the P1000 will also provide 
long-term product reliability and the piece of mind 
that  connected  equipment  is  safe  from  electrical 
disturbances.
In the event of abnormal operation with the P1000, 
please refer to the following suggestions:
Unit will not turn on
1. Check the obvious. Is it plugged in and is the 
AC wall outlet live? This can easily be tested by 
using  a  functional  lamp.  Plug  the  lamp  into  the 
wall  outlet  and  see  if  the  light  works.  If  not,  the 
P1000 may be plugged into a switched outlet, or 
perhaps the circuit breaker feeding the outlet has 
tripped and needs resetting.
2. After plugging the unit into the wall, the display 
will  read  “WAIT”  for  several  seconds  to  initialize 
its circuitry. The P1000 will only become activated 
after  pressing  the  front  panel  power  button.  Be 
sure that the unit is both plugged into the wall and 
turned on by the front panel power button.
3. Check the Main Fuse. The chances of the Power 
Plant’s  main  fuse  being  blown  are  very  remote. 
However,  if  the  Main  Fuse  is  blown,  the  P1000 
will  be  completely  inoperable. To  check  the  fuse 
locate the section of the back panel labeled “Main 
Fuse.”  Unplug  the  unit  from  the  wall,  remove 
the fuse and check its conductivity. If necessary, 
replace the fuse and try powering up the P1000. 
If the main fuse is blown and a replacement fuse 
does not solve the problem, please contact your 
dealer for additional service.
The Regenerator outlets are passing AC, but the 
Filtered AC outlets are not functioning
Check  the  Protection  Fuse.  To  check  the  fuse 
locate  the  section  of  the  back  panel  labeled 
“Protection  Fuse.”  Unplug  the  unit  from  the 
wall
, remove the fuse and check its conductivity. 
If  necessary,  replace  the  fuse  and  try  powering 
9
1. Filtered AC zone
One  Power  Port  duplex  receptacle  provides  two 
outlets  for  filtered  AC.  The  filtered  AC  zone  will 
pass as much current as a 15 amp wall receptacle 
can provide, up to 1800 watts. 
The controls for frequency, voltage, and MultiWave 
setting do not affect the Filtered AC zone outlets. 
This  power  zone  should  be  used  for  very  high 
current draw products which require more power 
than the Regenerated AC zone will provide.
 
The  Filtered  AC  zone  will  always  pass  power 
regardless of the front panel power status or fault 
status. 
2. PS Bus 
The  P1000  comes  equipped  with  a  built  in  PS 
Bus. The PS Bus allows other PS Audio products 
equipped with a PS Bus to communicate via stan-
dard RJ11 “twisted end” crossover cable.
3 & 5. Main and Protection Fuses 
The  main  fuse  is  a  15 Amp  slow  blow. The  pro-
tection  fuse  is  a  1  Amp  fast  blow.  Both  can  be 
removed  by  inserting  a  flat  device  into  the  fuse 
holder and twisting counter-clockwise.
4. IEC AC Power Inlet 
15 Amp IEC standard male socket.
6. Regenerated AC zone
Four Power Port duplex receptacles provide eight 
outlets for regenerated AC. The Regenerated AC 
zone  will  produce  up  to  1000  watts  peak  power 
depending on the type of load. 
The Regenerated AC zone will only pass power if 
the front panel power switch is on and the P1000 
is not in a fault status mode. 
MultiWave  II  and  the  associated  TubeWave  and 
AutoWave waveforms are only available through 
the Regenerated AC Zone outlets.
4
Rear Panel Layout