18.17 User configuration bytes
A number of user-configurable features of the P89LPC932A1 must be defined at 
power-up and therefore cannot be set by the program after start of execution. These 
features are configured through the use of an Flash byte UCFG1 shown in 
Read Sector CRC
Input parameters:
ACC = 05h
R7= sector address
Return parameter(s):
R4= CRC bits 31:24
R5= CRC bits 23:16
R6= CRC bits 15:8
R7= CRC bits 7:0 (if no error)
R7= error status (if error)
Carry= set on error, clear on no error
Read Global CRC
Input parameters:
ACC = 06h
Return parameter(s):
R4= CRC bits 31:24
R5= CRC bits 23:16
R6= CRC bits 15:8
R7= CRC bits 7:0 (if no error)
R7= error status (if error)
Carry= set on error, clear on no error
Read User Code
Input parameters:
ACC = 07h
R4= address (MSB)
R5= address (LSB)
Return parameter(s):
R7= data
Table 99:
IAP function calls
 …continued
IAP function
IAP call parameters
Table 100: Flash User Configuration Byte (UCFG1) bit allocation
Bit
7
6
5
4
3
2
1
0
Symbol
WDTE
RPE
BOE
WDSE
-
FOSC2
FOSC1
FOSC0
Unprogrammed 
value
0
1
1
0
0
0
1
1
Table 101: Flash User Configuration Byte (UCFG1) bit description
Bit  Symbol
Description
0
FOSC0
CPU oscillator type select. See 
 for additional information. Combinations other than those 
shown in 
 are reserved for future use should not be used.
1
FOSC1
2
FOSC2
3
-
reserved