Philips 8-bit microcontroller with two-clock 80C51 core UM10109 Manual De Usuario

Descargar
Página de 133
 
© Koninklijke Philips Electronics N.V. 2005. All rights reserved.
User manual
Rev. 02 — 23 May 2005 
38 of 133
Philips Semiconductors
UM10109
P89LPC932A1 User manual
 
6.1 Reset vector
Following reset, the P89LPC932A1 will fetch instructions from either address 0000h or the 
Boot address. The Boot address is formed by using the Boot Vector as the high byte of the 
address and the low byte of the address = 00h. The Boot address will be used if a UART 
break reset occurs or the non-volatile Boot Status bit (BOOTSTAT.0) = 1, or the device has 
been forced into ISP mode. Otherwise, instructions will be fetched from address 0000H.
7.
Timers 0 and 1
The P89LPC932A1 has two general-purpose counter/timers which are upward compatible 
with the 80C51 Timer 0 and Timer 1. Both can be configured to operate either as timers or 
event counters (see 
). An option to automatically toggle the Tx pin upon timer 
overflow has been added.
In the ‘Timer’ function, the timer is incremented every PCLK.
In the ‘Counter’ function, the register is incremented in response to a 1-to-0 transition on 
its corresponding external input pin (T0 or T1). The external input is sampled once during 
every machine cycle. When the pin is high during one cycle and low in the next cycle, the 
count is incremented. The new count value appears in the register during the cycle 
following the one in which the transition was detected. Since it takes two machine cycles 
(four CPU clocks) to recognize a 1-to-0 transition, the maximum count rate is 
1
4
 of the 
CPU clock frequency. There are no restrictions on the duty cycle of the external input 
signal, but to ensure that a given level is sampled at least once before it changes, it should 
be held for at least one full machine cycle.
The ‘Timer’ or ‘Counter’ function is selected by control bits TnC/T (x = 0 and 1 for Timers 0 
and 1 respectively) in the Special Function Register TMOD. Timer 0 and Timer 1 have five 
operating modes (modes 0, 1, 2, 3 and 6), which are selected by bit-pairs (TnM1, TnM0) 
in TMOD and TnM2 in TAMOD. Modes 0, 1, 2 and 6 are the same for both 
Timers/Counters. Mode 3 is different. The operating modes are described later in this 
section.
Table 19:
Timer/Counter Mode register (TMOD - address 89h) bit allocation
Bit
7
6
5
4
3
2
1
0
Symbol
T1GATE
T1C/T
T1M1
T1M0
T0GATE
T0C/T
T0M1
T0M0
Reset
0
0
0
0
0
0
0
0
Table 20:
Timer/Counter Mode register (TMOD - address 89h) bit description
Bit  Symbol
Description
0
T0M0
Mode Select for Timer 0. These bits are used with the T0M2 bit in the TAMOD register to determine the 
Timer 0 mode (see 
).
1
T0M1
2
T0C/T
Timer or Counter selector for Timer 0. Cleared for Timer operation (input from CCLK). Set for Counter 
operation (input from T0 input pin).
3
T0GATE Gating control for Timer 0. When set, Timer/Counter is enabled only while the INT0 pin is high and the TR0 
control pin is set. When cleared, Timer 0 is enabled when the TR0 control bit is set.