10.9 Break detect
A break detect is reported in the status register (SSTAT). A break is detected when any 11 
consecutive bits are sensed low. Since a break condition also satisfies the requirements 
for a framing error, a break condition will also result in reporting a framing error. Once a 
break condition has been detected, the UART will go into an idle state and remain in this 
idle state until a stop bit has been received. The break detect can be used to reset the 
device and force the device into ISP mode by setting the EBRR bit (AUXR1.6)
Table 50:
Serial Port Control register (SCON - address 98h) bit allocation
Bit
7
6
5
4
3
2
1
0
Symbol
SM0/FE
SM1
SM2
REN
TB8
RB8
TI
RI
Reset
x
x
x
x
x
x
0
0
Table 51:
Serial Port Control register (SCON - address 98h) bit description
Bit  Symbol
Description
0
RI
Receive interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or 
approximately halfway through the stop bit time in Mode 1. For Mode 2 or Mode 3, 
if SMOD0, it is set near the middle of the 9th data bit (bit 8). If SMOD0 = 1, it is set 
near the middle of the stop bit (see SM2 - SCON.5 - for exceptions). Must be 
cleared by software.
1
TI
Transmit interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or 
at the stop bit (see description of INTLO bit in SSTAT register) in the other modes. 
Must be cleared by software.
2
RB8
The 9th data bit that was received in Modes 2 and 3. In Mode 1 (SM2 must be 0), 
RB8 is the stop bit that was received. In Mode 0, RB8 is undefined.
3
TB8
The 9th data bit that will be transmitted in Modes 2 and 3. Set or clear by software 
as desired.
4
REN
Enables serial reception. Set by software to enable reception. Clear by software to 
disable reception.
5
SM2
Enables the multiprocessor communication feature in Modes 2 and 3. In Mode 2 or 
3, if SM2 is set to 1, then Rl will not be activated if the received 9th data bit (RB8) 
is 0. In Mode 0, SM2 should be 0. In Mode 1, SM2 must be 0.
6
SM1
With SM0 defines the serial port mode, see 
.
7
SM0/FE
The use of this bit is determined by SMOD0 in the PCON register. If SMOD0 = 0, 
this bit is read and written as SM0, which with SM1, defines the serial port mode. If 
SMOD0 = 1, this bit is read and written as FE (Framing Error). FE is set by the 
receiver when an invalid stop bit is detected. Once set, this bit cannot be cleared 
by valid frames but is cleared by software. (Note: UART mode bits SM0 and SM1 
should be programmed when SMOD0 is logic 0 - default mode on any reset.)
Table 52:
Serial Port modes
SM0, SM1
UART mode
UART baud rate
00
Mode 0: shift register
CCLK
16
 (default mode on any reset)
01
Mode 1: 8-bit UART
Variable (see 
)
10
Mode 2: 9-bit UART
CCLK
32
 or 
CCLK
16
11
Mode 3: 9-bit UART 
Variable (see 
)