10.12 More about UART Modes 2 and 3
Reception is the same as in Mode 1.
The signal to load SBUF and RB8, and to set RI, will be generated if, and only if, the 
following conditions are met at the time the final shift pulse is generated. (a) RI = 0, and 
(b) Either SM2 = 0, or the received 9th data bit = 1. If either of these conditions is not met, 
the received frame is lost, and RI is not set. If both conditions are met, the received 9th 
data bit goes into RB8, and the first 8 data bits go into SBUF.
10.13 Framing error and RI in Modes 2 and 3 with SM2 = 1
If SM2 = 1 in modes 2 and 3, RI and FE behaves as in the following table.
Fig 27. Serial Port Mode 1 (only single transmit buffering case is shown).
transmit
start
bit
stop bit 
INTLO = 0
TX clock
write to
SBUF 
shift
TxD
TI
D0
D1
D5
D2
D6
D3
D4
D7
receive
RX
clock
shift
RI
start
bit
stop bit
RxD
D0
D1
D5
D2
D6
D3
D4
D7
002aaa926
÷16 reset
INTLO = 1
Fig 28. Serial Port Mode 2 or 3 (only single transmit buffering case is shown).
transmit
start
bit
stop bit
stop bit
TX clock
write to
SBUF 
shift
TxD
TI
D0
D1
D5
D2
D6
D3
D4
D7
receive
RX
clock
shift
RI
start
bit
RxD
D0
D1
D5
D2
D6
D3
D4
D7
002aaa927
TB8
RB8
÷16 reset
INTLO = 0
INTLO = 1
SMOD0 = 0
SMOD0 = 1