Installation and commissioning
 
23
8
.05 
Basic position of the machine drive unit  
8
.05.01 
On machines with PicoDrive and control unit P41 PD2
 
● Switch on the machine.
 
● Call up the parameter input by pressing the "scroll" key.
 
● To switch the function keys to input (LED in the TE key lights up), press the TE key.
 
● By pressing the corresponding +/- keys, select parameter "798" and service level C, 
see Chapter Selecting the User Level in the separate Control Panel Instruction Manual.
 
● Select parameter "799" by pressing the corresponding +/- keys.
 
● Check whether the value is set at "2" and alter if necessary.
 
● Switch the machine off and then on again.
 
● Select parameter "800" by pressing the corresponding +/- keys.
 
● Check whether the value is set at "0" (balance wheel turns towards the operator) and alter 
if necessary.
 
● Select parameter "802" by pressing the corresponding +/- keys.
 
● Check whether the value is set at "0" (= no reduction ratio) and alter if necessary.
 
● .By pressing the corresponding +/- key, select parameter "700"
 
● Sew a stitch by operating the pedal.
 
● Turn the balance wheel in the sewing direction until the descending needle is level with 
the top edge of the needle plate.
 
● Conclude the adjustment of the sewing motor by pressing the "scroll" key
 
8
.05.02 
With drive system MD-4-58-220-CE
 
● Press and hold button and switch on machine
 
● Parameter 176 is displayed.
 
● Call up parameter 181.
 
● Call up input level.
 
● Sew a stitch with the pedal function.
 
● Turn the handwheel in rotational direction until the needle point (approaching from above) 
is on the upper edge of the needle plate.
 
● Confi rm entry.
 
● Call up parameter 192.
Call up input level.
Press button D+ to turn function "off".
Press button "S" to exit input.