Toshiba TOSVERT VF-S11 Manual De Instrucciónes

Descargar
Página de 81
E6581160
67
7
Q
Table of input terminal functions 3
Function
No.
Code
Function
Action
54
STN
Coast stop (gate off)
ON: Coast stop (gate off)
55
RESN
Inversion of RES
ON: Acceptance of reset command
OFF
→ ON: Trip reset
56
F+ST
Combination of forward run and standby
ON: Simultaneous input from F and ST
57
R+ST
Combination of reverse run and standby
ON: Simultaneous input from R and ST
58
AD3
Acceleration/deceleration 3 selection
ON: Acceleration/deceleration 3
OFF: Acceleration/deceleration 1 or 2
59
F+AD3
Combination of forward run and
acceleration/deceleration 3
ON: Simultaneous input from F and AD3
60
R+AD3
Combination of reverse run and
acceleration/deceleration 3
ON: Simultaneous input from R and AD3
61
OCS2
Forced switching of stall prevention level 2
ON: Enabled at the value of H
OFF: Enabled at the value of H
62
HDRY
Holding of RY-RC terminal output
ON: Once turned on, RY-RC are held on.
OFF: The status of RY-RC changes in real time
according to conditions.
63
HDOUT
Holding of OUT-NO terminal output
ON: Once turned on, OUT-NO are held on.
OFF: The status of OUT-NO changes in real time
according to conditions.
64
PRUN
Cancellation (clearing) of operation command from
panel
0: Operation command canceled (cleared)
1: Operation command retained
65
ICLR
PID control integral value clear
ON: PID control integral value always zero
OFF: PID control permitted
Q
Table of output terminal functions 1
Function
No.
Code
Function
Action
0
LL
Frequency lower limit
ON: The output frequency is above the NN set
value.
OFF: The output frequency is equal to or less than
the NN set value.
1
LLN
Inversion of frequency lower limit
Inversion of LL setting
2
UL
Frequency upper limit
ON: Output frequency is equal to or higher than
WN
 value.
OFF: Output frequency is lower than WN value.
3
ULN
Inversion of frequency upper limit
Inversion of UL setting
4
LOW
Low-speed detection signal
ON: Output frequency is equal to or higher than
H
 value.
OFF: Output frequency is lower than H
value.
5
LOWN
Inversion of low-speed detection signal
Inversion of LOW setting
6
RCH
Designated frequency attainment signal
(completion of acceleration/deceleration)
ON: The output frequency is equal to or less than
the specified frequency ± frequency set with
H
.
OFF: The output frequency is above the specified
frequency ± frequency set with H.
7
RCHN
Inversion of designated frequency attainment
signal (inversion of completion of
acceleration/deceleration)
Inversion of RCH setting
8
RCHF
Set frequency attainment signal
ON: The output frequency is equal to or less than
the frequency set with H ± H.
OFF: The output frequency is above the frequency
set with H ± H.
9
RCHFN
Inversion of set frequency attainment signal
Inversion of RCHF setting
10
FL
Failure signal (trip output)
ON: When inverter is tripped
OFF: When inverter is not tripped
11
FLN
Inversion of failure signal (inversion of trip output)
Inversion of FL setting