E6581160
69
7
Q
Table of output terminal functions 3
Function
No.
Code
Function
Action
35
FCVIBN
Inversion of frequency VIB selection
Inversion of FCVIB
36
FLR
Fault signal (put out also at the time of a retry)
ON: When inverter trips or retries
OFF: When inverter does not trip or retry
37
FLRN
Inversion of failure signal (put out also at the time
of a retry)
Inversion of FLR
38
OUT0
Specified data output 1
ON: Specified data from remote control FA50:
BIT0= 1
OFF: Specified data from remote control FA50:
BIT0= 0
39
OUT0N
Inversion of specified data output 1
Inversion of OUT0 setting
40
OUT1
Specified data output 2
ON: Specified data from remote control FA50:
BIT1= 1
OFF: Specified data from remote control FA50:
BIT1= 0
41
OUT1N
Inversion of specified data output 2
Inversion of OUT1 setting
42
COT
Cumulative operation time alarm
ON: Cumulative operation time is equal to or
longer than H
OFF: Cumulative operation time is shorter than
H
43
COTN
Inversion of cumulative operation time alarm
Inversion of COT
44
LTA
Parts replacement alarm
ON: Calculation for parts replacement time is
equal to or longer than the preset time
ON: Calculation for parts replancement time is
shorter than the preset time
45
LTAN
Inversion of replacement alarm
Inversion of LTA
46
BR
Braking sequence output
ON: Braking retention signal
OFF: Braking release signal
47
BRN
Inversion of braking sequence output
Inversion of BR
48
LI1
F terminal input signal
ON: The signal input to F terminal is ON
OFF: The signal input to F terminal is OFF
49
LI1N
Inversion of F terminal input signal
Inversion of LI1
50
LI2
R terminal input signal
ON: The signal input to R terminal is ON
OFF: The signal input to R terminal is OFF
51
LI2N
Inversion of R terminal input signal
Inversion of LI2
52
PIDF
Signal in accordance of frequency command
ON: Frequency commanded by HOQF or
H
 and that by VIA show the same
value.
OFF: Frequency commanded by HOQF or
H
 and that by VIA show different
values.
53
PIDFN
Inversion of signal in accordance of frequency
command
Inversion of PIDF setting
54
MOFF
Undervoltage detection
ON: Undervoltage detected
OFF: Other than undervoltage
55
MOFFN
Inversion of undervoltage detection
Inversion of MOFF
56-253
Disabled
Invalid settings, always OFF (ignored)
Invalid settings, always OFF (ignored)
254
AOFF
Always OFF
Always OFF
255
AON
Always ON
Always ON