Tektronix Ventilation Hood AWG710 Manual De Usuario

Descargar
Página de 580
Waveform Programming Language
AWG710&AWG710B Arbitrary Waveform Generator User Manual
3-187
Waveform Files
Some commands accept a waveform file name enclosed in double quotes. For 
example: "sinewave.wfm". Observe the following rules when using waveform 
expressions in equations:
„
A quoted string can include any character defined in the 7–bit ASCII character 
set.
„
A numeric value can be embedded in a string in the following format:
“AA”:i:“.WFM”
If the value of i equals 10, the string “AA10.WFM” will result. Before 
conversion into the string, the value is rounded to the nearest integer.
„
One waveform expression can include a maximum of 10 input files. If the same 
file name appears more than once in a single waveform expression, that file is 
considered as one file. An exception to this is that “A.WFM” and 
“A.WFM”.marker1 are two different files.
„
Signal names, as well as variables, are permitted in a waveform expression. 
Waveform expressions enable you to specify calculation between waveforms 
in a similar manner as ordinary expressions. For example, if you code the 
following:
“A.WFM” = sin(2*pi*scale) + “B.WFM”
A.WFM is produced as the sum of the sinewave equation and B.WFM 
waveforms.
Waveform Expression
The output name, placed to the left of an ‘=’, and the name used in the expression 
to the right of an ‘=’ is a <signal–name>. The marker data may be specified as 
follows in addition to the name of an ordinary waveform file:
“A.WFM”.marker2 = “A.WFM” > “B.WFM” > “B.WFM”
In this example, 1 is set if the A.WFM value as the A.WFM marker 2 value is larger 
than the B.WFM value; 0 is set otherwise. (This is the same as for the  compare 
function of the editor.) The A.WFM analog data is unchanged.
“B.WFM”.marker1 = “A.WFM”.marker1 + “A.WFM”.marker2
In this example, B.WFM’s marker1 is set if either marker 1 or 2 of A.WFM is 1.