Nortel Networks Video Gaming Accessories 553-3001-211 Manual De Usuario

Descargar
Página de 896
Page 102 of 894
 Option settings
NT1R20 Off-Premise Station card
Table 13 lists option settings for the NT1R20 Off-Premise Station analog 
card.
Table 13
OPS analog line card configuration (Part 1 of 3)
Application
On-premise station (ONS)
Off-premise station (OPS)
Class of Service 
(CLS) (Note 1)
ONP
OPX
Loop resistance 
(ohms)
0–460
0–2300 (Note 2)
Jumper strap 
setting (Note 6)
Both JX.0 and JX.1 
off
Both JX.0 and JX.1 
off
Both JX.0 and JX.1 
on
Note 1: Configured in the Analog (500/2500-type) Telephone Administration program (LD 10).
Note 2: The maximum signaling range supported by the OPS analog line card is 2300 ohms.
Note 3: Loss of untreated (no gain devices) metallic line facility. Upper loss limits correspond to 
loop resistance ranges for 26 AWG wire.
Note 4: Default software impedance settings are:
ONP CLS
OPX CLS
TIMP:
600 ohms
600 ohms
BIMP:
600 ohms
3COM2
Note: Gain treatment, such as a voice frequency repeater (VFR) is required to limit the actual 
OPS loop loss to 4.5 dB, maximum. VFR treatment of metallic loops having untreated loss 
greater than 15 dB (equivalent to a maximum signaling range of 2300 ohms on 26 AWG wire) is 
not recommended.
Note: Jumper strap settings JX.0 and JX.1 apply to all eight units; “X” indicates the unit 
number, 0–7. “Off” indicates that a jumper strap is not installed across both pins on a jumper 
block. Store unused straps on the OPS analog line card by installing them on a single jumper 
pin as shown below:  
553-5924
Jumper block
Jumper strap
Jumper pin