Electrical specifications
Table 88 provides a technical summary of the E1 line interface. Table 89 on 
 lists the maximum power consumed by the card.
E1 channel specifications
Table 88 provides specifications for the 30 E1 channels. Each characteristic 
is set by a dip switch. See “Installation and Configuration” on 
a discussion of the corresponding dip switch settings.
Table 88
LEI card — line interface unit electrical characteristics
Characteristics
Description
Framing
CRC-4 or FAS, only
Coding
AMI or HDB3
Signaling
Loop or ground start
A/B robbed-bit
Distance to LTU
0-199.6 meters (0-655 feet)