 NT5D33 and NT5D34 Lineside E1 Interface cards
Power requirements
Table 89 shows the voltage and maximum current that the LEI requires from 
the backplane. One NT8D06 IPE Power Supply AC or NT6D40 IPE Supply 
DC can supply power to a maximum of eight LEIs.
Foreign and surge voltage protections
In-circuit protection against power line crosses or lightning strikes is not 
provided on the LEI. It does, however, have protection against accidental 
shorts to –52 V dc analog lines.
When the card is used to service off-premise terminal equipment through the 
public telephone network, install a Line Termination Unit (LTU) as part of 
the terminal equipment to provide external line protection.
Environmental specifications
Table 90 shows the environmental specifications of the LEI.
Table 89
LEI card – power required
Voltage
Max. Current
5.0 V dc
1.6 Amp
+15.0 V dc
150 mA
-15.0 V dc
150 mA
Table 90
LEI card – environmental specifications (Part 1 of 2)
Parameter
Specifications
Operating temperature – normal
15° to +30° C (+59° to 86° F), ambient
Operating temperature – short term
10° to +45° C (+50 to 113° F), ambient
Operating humidity – normal
20% to 55% RH (non-condensing)
Operating humidity – short term
20% to 80% RH (non condensing)