Motion 42-02-S028 Manual De Usuario

Descargar
Página de 20
Communication Connections
7
PTC/PHC
1. Connect the external Ethernet cable to Ethernet Port A on the USN-BASE assembly.
2. The boards in the controller are connected along a ribbon cable bus. Connect the M2C 
assembly’s “From PCA” (JP3) to the last controller board on the bus using supplied rib-
bon cable.
3. Connect the M2C assembly’s CAN2 port to the “Internal Network” (J5) connector on the 
USN-BASE assembly using the C-RJ-11 cable .
4. For Duplex, connect both CAN2 ports on the M2C assembly to supplied splitter. Then 
plug the splitter into “Internal Network” (J5) connector on USN-BASE assembly. 
5. Press RSTA to reset the USN board so that it will read its new connections.
6. With the Function Switch F8 switch UP (all others down), press N to cycle through the 
menu to verify that information is correct.
• MC-USN  version
• iReport version
• Number of cars connected
• Number of cars 
• Number of floors
The controller is now ready to communicate.
The last board on the 
ribbon cable bus will 
have an empty socket.
Make the connection 
from this socket.