Motion 42-02-S028 Manuel D’Utilisation
Communication Connections
7
PTC/PHC
1. Connect the external Ethernet cable to Ethernet Port A on the USN-BASE assembly.
2. The boards in the controller are connected along a ribbon cable bus. Connect the M2C
2. The boards in the controller are connected along a ribbon cable bus. Connect the M2C
assembly’s “From PCA” (JP3) to the last controller board on the bus using supplied rib-
bon cable.
bon cable.
3. Connect the M2C assembly’s CAN2 port to the “Internal Network” (J5) connector on the
USN-BASE assembly using the C-RJ-11 cable .
4. For Duplex, connect both CAN2 ports on the M2C assembly to supplied splitter. Then
plug the splitter into “Internal Network” (J5) connector on USN-BASE assembly.
5. Press RSTA to reset the USN board so that it will read its new connections.
6. With the Function Switch F8 switch UP (all others down), press N to cycle through the
menu to verify that information is correct.
• MC-USN version
• iReport version
• Number of cars connected
• Number of cars
• Number of floors
• iReport version
• Number of cars connected
• Number of cars
• Number of floors
The controller is now ready to communicate.
The last board on the
ribbon cable bus will
have an empty socket.
ribbon cable bus will
have an empty socket.
Make the connection
from this socket.
from this socket.