Motion 42-02-S028 Manual De Usuario

Descargar
Página de 20
MCE Universal Serial Network
2   Manual # 42-02-S028 A1
USN Installation
Installation instructions include:
• MCE IMC and PTC/PHC Controls
• Motion 3000ES Escalator Controls
• USN Power Connection
Note
After mounting USN components in your equipment, ensure that no serial, ethernet, or CAN 
connections are made to the device.  Only power should be connected during initial setup.
IMC, PTC, PHC Installation 
The Universal Serial Network (USN) converts legacy MCE communication protocols to the lat-
est MCE monitoring, reporting, and building management compatible protocols. For IMC, only 
the USN-BASE assembly  and power transformer are required. For programmable (PTC/PHC) 
controllers, one M2C assembly is required for each controller in addition to the USN-BASE 
assembly and power transformer. 
USN-BASE Assembly
PCA JP3
CAN 2
AC1/AC2
Port B J7
Ethernet
Port A
J5
Power transformer -
6-feet power leads are provided but are 
not connected to the transformer. Cut 
leads to length required and connect to 
transformer per local requirements.
M2C Assembly