Motorola PTP 400 Series Manual De Usuario

Descargar
Página de 208
 
 
151
11.3  Testing Your Installation 
If you have followed the above instructions you will have wired your system to the following 
diagram: 
Ethernet 
 
1 Orange/White 
3 Green/White 
6 Green 
8 Brown 
4 Blue 
5 Blue/White 
7 Brown/White 
2 Orange 
Ethernet 
Ethernet 
LED/Reset 
signalling 
0V Floating
36V-55V 
Chassis 
1 Orange/White
3 Green/White
6 Green
8 Brown
4 Blue
5 Blue/White
7 Brown/White
2 Orange
Ethernet 
LED/Reset 
signalling 
0V Floating 
36V-55V 
PIDU Plus 
ODU
Surge Arrestor
ALPU-ORT 
Cable Screen 
Tower 
T-568B 
T-568B 
CON3
CON4
CON1
CON2
1
2
3
6
4
5
7
8
3
5
2
4
8
1
6
7
 
Figure 82 - Simplified Circuit Diagram (Only One Transtector Shown For Clarity) 
11.3.1 Pre-Power Testing 
Before plugging in the RJ45 to the PIDU Plus, check the following impedances at the RJ45: 
1.  Check the cable resistance between pins 7 and 4 at the RJ45. Check against column 2 in 
2.  Check the resistance between pins 8 and 5 at the RJ45. Check against column 3 in the 
3.  Check the resistance between pins 7 and 8 at the RJ45. The value should be greater 
than 1000 ohms.