7.7.5  Grounding the Installation
 
 
The Outdoor Unit (ODU) for the PTP 400 Series Bridge must be properly grounded to protect 
against power surges. It is the user’s responsibility to install the equipment in accordance with 
Section 810 of the National Electric Code, ANSI/NFPA No.70-1984 or Section 54 of the 
Canadian Electrical Code or the National Electrical Code in the country of installation. These 
codes describe correct installation procedures for grounding the outdoor unit, mast, lead-in 
wire and discharge unit, size of grounding conductors and connection requirements for 
grounding electrodes. It is recommended that installation of the outdoor unit be contracted to 
a professional installer. See Section 11 “Lightning Protection” for recommended grounding 
kits. Failure to follow these Lightning Protection recommendations will invalidate your 
warranty if damage to the system is found to be caused by lightning. 
7.7.6  Making the ODU Connection at the PTP 400 Series Bridge PIDU Plus  
The ODU is connected to the PIDU Plus by means of a concealed RJ45 connector. The RJ45 
connection has been placed inside the PIDU Plus hinged cover to prevent the user 
inadvertently plugging other equipment into the ODU RJ45 socket.  
Warning: Plugging other equipment into the ODU RJ45 socket may damage the equipment 
due to the non-standard techniques employed to inject DC power into the 100BaseT 
connection between the PIDU Plus and ODU. Plugging the ODU into other equipment may 
damage the ODU and/or the other equipment.  
 
Step 1: Undo the retaining screw and hinge 
back the cover. 
 
Step 2: Plug in the ODU to PIDU Plus Cable 
ensuring that it snaps home