Lexibook SM1760 Manual De Introducción

Descargar
Página de 10
Copyright © Lexibook 2006 
SM1760IM0036 GB17
English
English
17
TROUBLESHOOTING
ACCESSORIES
SPECIFICATIONS
Copyright © Lexibook 2006 
SM1760IM0036 GB18
18
Problem:
1. The main unit cannot receive radio control 
    DCF-77 or MSF signals to update the clock.
2. The temperature measurements of the remote 
    sensor and receiver do not match.
3. Temperature reading of outdoor remote sensor 
    seems too high.
4. Receiver is no longer receiving remote sensor 
    signals or display.
5. An abnormal operation has been observed and 
    certain functions do not work. 
Solution:
1. Place the clock away from metal objects or 
    electrical appliances such as TVs, computers, 
    monitors, etc. Trigger the scan manually by 
    holding the Min/- key [3] for 3 seconds.
2. Wait for about 1-2 minutes to ensure the 
    remote sensor and receiver are in phase. 
    Otherwise, re-synchronize receiver by holding 
    CHN [5] for 3 seconds until a beep is heard.
3. Ensure the remote sensor is out of direct 
    sunlight, and away from sources of heat.
4. Repeat the learning procedures.
- Temperature may be below -30°C.
- Batteries in remote sensor may need 
  changing.
- Move remote sensor closer to the receiver.
- Make sure remote sensor is away from 
  sources of electrical disturbance.
5. Reset the unit by replacing the batteries in both 
    the transmitters and receiver. 
Additional sensors:
Measure temperature and hygrometry in other places!
- Upstairs
- In the baby's bedroom
- In the basement
- In the garden
- In another room
To order, phone the Lexibook office located in your country or browse  www.lexibook.com.
Weather Station Receiver SM1760
Battery Type:  
 
3 X1.5V AA batteries
Temp.Range:  
 
-20 C to +55 C
Measurement Accuracy:   
+/- 1 C
   
 
 
Within measuring range of 0 to 40 C
Resolution:   
 
0.1 C
Humidity Range: 
 
15% to 95%
Measurement Accuracy:   
+/- 5%
Resolution:   
 
1%
Weather Station Transmitter ASM20
Battery Type:  
 
2 X1.5V AA batteries
Temp. Range: 
 
-30 C to + 70 C
Humidity Range 
 
15% to 95%
Transmission Frequency:   
433.92MHz
Transmission Range: 
 
Up to 40 meters in open area.