IBM Partner Pavilion Vitrual Switch Extension BMD00082 Manual De Usuario

Descargar
Página de 166
SmartConnect User’s Guide
56  
„
  Chapter 4: Stacking
BMD00082, February 2009
2.
Verify that the software push is complete. Use either the CLI or the BBI:
„
From the BBI, go to Information > Stack and view the Image Push Status Information at 
the bottom of the page, or
„
From the CLI, use following CLI command to verify the software push: 
/info/stack/pushstat
3.
Reboot all switches in the stack. From the BBI, select System Settings > Boot Man-
agement. Click Reboot Stack. 
4.
Once the switches in the stack have rebooted, verify that all of them are using the same 
version of firmware. Using the BBI, open Information > Stack and view the Switch 
Firmware Versions Information.
Image 1 transfer status info:
        Switch 00:16:60:f9:33:00:
                last receive successful
        Switch 00:17:ef:c3:fb:00:
                not received - file not sent or transfer in progress
Image 2 transfer status info:
        Switch 00:16:60:f9:33:00:
                last receive successful
        Switch 00:17:ef:c3:fb:00:
                last receive successful
Boot image transfer status info:
        Switch 00:16:60:f9:33:00:
                last receive successful
        Switch 00:17:ef:c3:fb:00:
                last receive successful
Config file transfer status info:
        Switch 00:16:60:f9:33:00:
                last receive successful
        Switch 00:17:ef:c3:fb:00:
                last receive successful