Honeywell Network Hardware NETAXS-123 Manual De Usuario

Descargar
Página de 76
32
www.honeywell.com
Installing the NetAXS-123 Panels
Installation
 lists the factory Add-On Board default settings for a door 3. These mappings should be used 
for the readers, inputs, and outputs when either a 1- or 2-door Add-On Board is attached to the 
board-to-board connector on the controller board.
Table 7:  Factory Default Configuration Settings for Door 3
Readers A and B share the same connection.
Notes:
• Reader LEDs, while they are outputs, should never be used to control anything other than their 
associated reader LEDs.
• Incorrect wiring of the reader to the panel can cause the panel to abnormally stop operating or 
to operate erratically.
Type
Purpose
Web 
Default 
Name
Terminal 
Block 
Label
Reader A
Reader B
Other
Input
Egress/
Request to 
Exit (REX)
Input 9: 
Door 2
Egress
IO-TB2
IN9 (REX)
Input 9
a
Input 9
a
Door Status
Input 10: 
Door 2 
Status
IO-TB2
IN10 (STS)
Input 10
a
Input 10
a
Reader 
Tamper
Input 11: 
Door 
TMPR-A
IO-TB3 
TMPR A
Input 11
Reader 
Tamper
Input 12: 
Door 
TMPR-B
IO-TB4 
TMPR B
Input 12
Output
Lock Relay
Output #11
IO-TB5
LOCK
Output 11
a
Output 11
a
Reader LED
Output #12
IO-TB7
LED
Output 12
a
Output 12
a
AUX Relay
Output #13
IO-TB5
AUX
Output 13
Reader 
Buzzer
Future 
Feature
IO-TB7
BZR
Output 14
a
Output 14
a