Honeywell Network Hardware NETAXS-123 Manual De Usuario

Descargar
Página de 76
34
www.honeywell.com
Installing the NetAXS-123 Panels
Installation
2. Use the following figure to wire the door strike/mag lock according to the power supply used. 
Be sure to use the S4 suppressor kits as shown below. 
Notes:
•   As shown in the illustration above, the Dry C terminal for the On-Board option should 
not be connected. Similarly on the External Power Supply side, the Return terminal 
should not be connected.
•   The On-Board option is used when jumpers are set for 12VDC. The External Power 
Supply options is used when the jumpers are set to External Power (see 
page 39 for details).
Return
Dr
y C
NO/NC
Locking 
Device
Return
Dr
y C
NO/NC
Locking 
Device
+ DC
OR
On-Board
+12VDC
Configuration
External 
Power Supply 
Configuration
   DC
S4
S4
S4