Graco 3A0591U Ram Packages Manual De Usuario

Descargar
Página de 38
Operation
3A0591U
17
Changing Drums
1.
Stop the pump. Close the air motor valve (BF). 
2.
Set the inflatable seal valve (BJ) to deflate.
3.
Set the director valve (BC) to UP to raise the ram 
plate. 
4.
Raise the ram plate until it is completely out of drum.
5.
If needed, use air assist (BG) to help lift the ram 
plate.
6.
Remove the empty drum.
7.
Inspect the ram plate and, if necessary, remove any 
remaining material or buildup.
8.
Place a full drum on ram base.
9.
Lower the ram, and adjust the position of the drum 
relative to the ram plate, as explained under Setting 
Inflatable Seal Pressure
 on
 page 14.
Shutdown
1.
Set the director valve (BC) to neutral.
2.
3.
Follow the pump shutdown instructions in your sep-
arate pump manual.
Moving parts can pinch, cut, or amputate fingers and 
other body parts. Keep your hands and fingers away 
from the priming piston, ram plate, and lip of drum dur-
ing operation and whenever the pump or ram is 
charged with air.
Excessive air pressure in the material drum could 
cause the drum to rupture, causing serious injury and 
equipment damage. The platen must be free to move 
out of the drum.
• Never use drum blowoff air assist with a damaged 
drum.
• Always deflate the seal prior to lifting ram plate or 
engaging air assist.