Troubleshooting
3A0591U
19
Troubleshooting
1.
Follow Pressure Relief Procedure, page 14.
2.
Check all possible remedies in the Troubleshooting
Chart before disassembling the pump.
Chart before disassembling the pump.
Problem
Cause
Solution
Ram will not raise or lower.
Closed air valve or clogged air line.
Open, clear.
Not enough ram air pressure.
Increase.
Worn or damaged piston.
Replace.
Hand valve closed or clogged.
Open, clear.
Ram raises and lowers too fast.
Air pressure is too high.
Decrease.
Travel rate is not properly adjusted.
Exposed Air Controls - open the
director valve less for slower travel,
more for faster travel.
Enclosed Air Controls - open the
needle valve on the muffler more for
slower downward travel, less for
faster downward travel.
director valve less for slower travel,
more for faster travel.
Enclosed Air Controls - open the
needle valve on the muffler more for
slower downward travel, less for
faster downward travel.
Air leaks around cylinder rod.
Worn rod seal.
Replace.
Fluid squeezes past ram plate wip-
ers.
ers.
Ram air pressure too high.
Decrease ram pressure.
Worn or damaged wipers.
Replace.
Inflatable seal pressure too low.
Increase seal pressure
Pump will not prime properly or
pumps air.
pumps air.
Closed air valve or clogged air line.
Open, clear.
Not enough air pressure.
Increase.
Worn or damaged piston.
Replace. See pump manual.
Hand valve closed or clogged.
Open, clear.
Hand valve is dirty, worn, or dam-
aged.
aged.
Clean, service.
Air assist valve will not hold drum
down or push plate up.
down or push plate up.
Closed air valve or clogged air line.
Open, clear.
Not enough air pressure.
Increase.
Valve passage clogged.
Clean.
Seal pressure builds when drum
tapers, activating the automatic pres-
sure relief.
tapers, activating the automatic pres-
sure relief.
Seal bleed-off valve (BL) is closed
Open. See Integrated Air Controls,
page 13.
page 13.