Setup
3A2894F
35
h.
Activate
 on the DM.
i.
Open the base (A) air motor slider valve.
j.
Increase the base (A) air motor regulator as 
required to have material flow out of the hose.
k.
Dispense the material into the waste container 
until the base (A) material hose is purged and 
free of air.
l.
Deactivate
 on the DM.
m. Close the base (A) air motor slider valve.
n.
Repeat steps a through m for the catalyst (B) 
hose. Refer to Integrated Air Controls
page 18, for visual clarity.
NOTE: Activate
 on the DM when prompted and all 
slider valves refer to the catalyst (B) air controls.