Managing Drives & Enclosures
183
4
Select the drive you want and press Enter.
The system confirms that you want to make the change. 
5
Select Yes and press Enter to make the change.
To make the drive display again, you must use Rescan. See 
G.10, ”Rescanning All Channels”, on 
page 206
. After you rescan, you must clear the metadata from the drive before you can use it in an array 
or as a spare. See 
F.1.2, ”Clearing Metadata from a Drive”, on page 177
.
F.1.8 Testing a Drive
This function issues a Test Unit Ready (TUR) command to the selected disk. This just tells you that the 
drive can respond, but it still may not be functioning properly.
To test a drive:
1
From the System Menu, select Utilities Menu and press Enter.
The Utilities Menu displays.
2
Select Drive Utilities Menu and press Enter.
The Drive Utilities Menu displays.
3
Select Test Unit Ready and press Enter
The Select Drive screen displays.
4
Select the drive you want and press Enter.
If the TUR was successful, TUR STATUS OK displays.
If the TUR was not successful, a failure message displays.
5
Press Esc to return to the Drive Utilities Menu.
F.2 Managing Enclosures
An enclosure management processor (EMP) is a device in the enclosure from which the Galaxy 65 
Subsystem can inquire about the enclosure’s environmental conditions such as temperature, power 
supply and fan status, and the presence or absence of disk drives. The Galaxy 65 Subsystem can also 
tell the EMP about RAID activities such as drive rebuilds and failed disk drives. 
If you have only one EMP, the configuration settings are automatically enabled when the Galaxy 65 
Subsystem is installed. No changes are required to the default configuration settings to support EMP. 
If you have more than one EMP, you must set up the EMP LUNs as described in the next section.
• Set the EMP LUN (see 
page 184
)
• Change additional EMP setting (see 
page 187
):
– Polling interval