DMC-1700/1800 
Chapter 4 - Software Tools and Communications  •  67 
Status Byte (hex) Condition
00 No 
interrupt 
D9 Watchdog 
timer 
activated 
DA Command 
done 
DB 
Application program done 
F0 thru FF 
User interrupt 
E1 thru E8 
Input interrupt 
C0 
Limit switch occurred 
C8 Excess 
position 
error 
D8 
All axis motion complete 
D7 
H axis motion complete 
D6 
G axis motion complete 
D5 
F axis motion complete 
D4 
E  axis motion complete 
D3 
W axis motion complete 
D2 
Z axis motion complete 
D1 
Y axis motion complete 
D0 
X axis motion complete 
 
The Galil drivers and communication DLL’s will service the interrupt and return the StatusByte.  Any host application 
that has been properly configured though a window message will then be notified.  When using the DMCShell control, 
the windows message will be retrieved and the StatusByte will be returned as an argument.  For example, when using the 
ActiveX toolkit DMCShell control with VB, the DMCShell1_DMCInterrupt() event procedure (shown below) will 
execute and pass the StatusByte in the argument.  When an interrupt occurs, this StatusByte can then be used in a case 
structure as the key to notify the host application of a specific event or condition.   
 
In the VB example below, the event procedure will display a message box every time the X-axis motion is complete, 
assuming the command EI1 was sent to the controller.  Note: the argument is returned as 208 since the status byte is 
returned as an integer (i.e. D0 hex = 208 decimal). 
 
Private Sub DMCShell1_DMCInterrupt(StatusByte As Integer) 
    
  
If StatusByte = 208 Then 
       
 
MsgBox "X axis complete" 
       
End If 
End Sub
 
Hardware Level Communications for ISA and PCI 
 
This section of the chapter describes in detail the structures used to communicate with the DMC-1700 and 
DMC-1800 controllers at the register interface level. The information in this section is intended for advanced 
programmers with extensive knowledge of ISA and PCI bus operation.  
 
Communications with the DMC-1700  
The DMC-1700 controller provides dual FIFO (first in first out) buffers, where a primary read/write FIFO is used for the 
main command input and response, and a secondary FIFO is used for read-only access to the data record. The primary 
read and write buffers are 512 characters deep, which permits sending multiple commands at high speeds ahead of their 
actual command processing by the DMC-1700.