Empire Comfort Systems CIBV-30-20 Manual De Usuario

Descargar
Página de 28
Page 26
15627-5-0807
Installing Optional CIB-2 Blower
  1.  Loosen, but do not remove, (4) hex-head screws located on 
the exterior, bottom of the appliance.
  2.  Position the blower assembly at the rear of the appliance. 
The blower assembly has (4) keyholes for attachment to the 
exterior, bottom of the appliance.
  3.  Place the large diameter holes in the keyholes over and behind 
the (4) hex-head screws that were loosened in Step 1. Push 
inward on the blower assembly to lock the keyholes into position 
behind  the  screws.  Tighten  (4)  hex-head  screws  to  secure 
blower assembly to exterior, bottom of the appliance.
  4.  Remove wire channel from rear cover by removing (4) hex-
head screws. Note: If optional blower is being installed during 
initial installation of appliance, the wire channel will not be 
attached to rear cover. (Refer to Wire Channel Installation
Page 13)
  5.  Attach fan control to FLAT, fan control bracket (Part 9A, Page 
27) with (2) 6 x 1/4" screws provided in hardware package.
  6.  Attach fan control with bracket onto the wire channel by using 
(2) 8 x 1/4" screws provided in hardware package.
  7.  Route wires from fan control and ON/OFF/REMOTE switch 
within wire channel.
  8.  When facing the rear of the appliance, align and insert fan 
control with bracket into 1 3/8" x 2" opening on the left side 
of the rear cover.
  9.  Attach  wire  channel  to  rear  cover  by  using 
(4)  hex-head  screws    removed  in  Step  4. 
(Refer to Wire Channel Installation, Page 13) 
 10. Insert AUTO/OFF/ON switch into rectangular notch on valve 
bracket. Be sure to insert AUTO/OFF/ON switch with letters 
(words) upright. (See wiring diagram)
 11. Attach 1/4" push-on terminal from blue wire on the fan control 
to the AUTO (top) tab on the switch.
 12. Attach 1/4" push-on terminal from black wire to the OFF 
(middle) tab on the switch.
 13. Attach  1/4"  push-on  terminal  from  white  wire  on  the  fan 
control to the ON (bottom) tab on the switch.
 14. Installation of optional CIB-2 blower is completed.
Fan Control
The  fan  control  is  a  non-adjustable  automatic  type.   The  fan 
control will require between 5 and 10 minutes of main burner 
operation before the fan control "closes" and activates the blower.  
The blower will continue to run between 5 and 10 minutes after 
the main burner shuts off, before the fan control "opens" and 
deactivates the blower.
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS