15627-5-0807
CAUTION: Label all wires prior to disconnection when servicing 
controls.  Wiring  errors  can  cause  improper  and  dangerous 
operation. Verify proper operation after servicing. 
WARNING:
Unplugging  of  blower  accessory  will  not  stop  the  heater 
from cycling.  To shut heater off:  Turn temperature dial  
or thermostat to lowest setting.  Turn knob on gas control 
to "OFF",  depressing slightly.  Do not force.
Cleaning
The blower wheel will collect lint and could require cleaning once 
a year. If the air output decreases or the noise level increases, it 
indicates a dirty wheel.
Blower Motor
The blower motor does not have oiling holes. Do not attempt to 
oil blower motor.
Wiring
The appliance, when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local codes, 
with the National Electrical Code, ANSI/NFPA 70 or Canadian 
Electrical  Code,  CSA  C22.1,  if  an  external  electrical  source 
is  utilized.  This  appliance  is  equipped  with  a  three-prong 
[grounding] plug for your protection against shock hazard 
and  should  be  plugged  directly  into  a  properly  grounded 
three-prong receptacle.  Do not cut or remove the grounding 
prong from this plug.  For an ungrounded receptacle, an adapter, 
which has two prongs and a wire for grounding, can be purchased, 
plugged into the ungrounded receptacle and its wire connected to 
the receptacle mounting screws.  With this wire  completing the 
ground, the appliance cord plug can be plugged into the adapter 
and be electrically grounded. 
PARTS LIST
Index   Part 
No. 
No. 
Description
  1 
R-1454 
Brass Bushing (4 Required) 
  2 
R-1499      Rubber Grommet (4 Required) 
  3 
CI-002     
Blower Housing 
  4 
R-1517      Tinnerman Clip (4 Required) 
  5 
R-2804-A    Blower Assembly 
  6 
CI-003     
Blower Housing Cover 
  7 
R-2099      Cord Set 
  8 
R-3767-A     Wire Harness 
 9A 
CI-004 
Fan Control Bracket
   
 
(Use with CIBV-30 and CIVF-25)
9B 
CI-325 
Fan Control Bracket
   
 
(Use with CIDV-30)
 10 
R-2503      Fan Control
 11 
R-2805      Auto/Off/On Switch
12 
CI-220 
Fan Control Shield
   
 
(Use with CIVF-25) 
 13 
R-1410      Bushing 7/8" Diameter