BlueStorm Installation Guide, Connect Tech Inc. 
 
Revision 0.10 
 
BlueStorm Installation Overview 
 
There are three stages to installing your BlueStorm card: 
 
1.
 
  
Interrupts and Memory selection will be set by the host computer’s BIOS and operating 
system. This section outlines jumper settings and configuration. 
 
2.
 
Installation involves the physical installation of the BlueStorm into your computer. Please 
note that you should configure any jumper settings prior to installing the board.  
 
3.
 
Load the appropriate driver for your Operating System, as found on the accompanying 
CD. Installation guides are also available on the CD to aid you in this process. 
  
Hardware Configuration 
Interrupts and Memory Address Selection 
All BlueStorm products are PCI cards. Therefore, the host computer’s BIOS will automatically 
set interrupts and memory addresses when you reboot after installation. 
 
RS-422/485 Electrical Interface Configuration 
Some BlueStorm adapters support RS-422/485 communication, as outlined below. (See Figure 1 
through to Figure 6 for configuration jumper block locations). It may be necessary to configure 
the card to match your particular wiring configuration. Please see the “Jumper Configuration for 
BlueStorm” section below for configuration examples. 
Full Duplex Mode 
In this mode, TxD+/- and RxD+/- are being driven to a known level at all times. This mode is 
typically used in point-to-point situations much like RS-232. 
Half Duplex Mode 
In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is 
disabled when data is being transmitted. This mode is typically used in either point-to-point 2-
wire connections OR in multi-drop 2-wire bus connections.  This mode requires software setup 
in 
Control Panel – System – Hardware – Device Manager – Ports – CTI PCI UART. 
 Click on 
Advanced
 under 
Port Settings
 after the driver is installed. (See multi-drop slave below).