Connect Tech BlueStorm Universal PCI Manual De Usuario

Descargar
Página de 27
BlueStorm Installation Guide, Connect Tech Inc. 
 
8                                                                                                                                                Revision 0.10 
 
Multi-drop Slave Mode 
In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is 
enabled at all times.  This mode is typically used in multi-drop 4-wire connections.  This mode 
requires software setup in 
Control Panel – System Properties – Hardware - Device Manager – Ports – CTI 
PCI UART
.  Click on 
Advanced
 under 
Port Settings
.  
Line Bias/Termination 
The RS-422/485 transceivers, both transmit and receive are optionally biased to produce a line 
level mark condition through jumper selectable resistors.  These options are typically used in 
multi-drop 4-wire connections. Termination may also be required depending on your wiring 
configuration. Each case must be evaluated to determine which options to enable. 
 
Jumper Block Diagrams for BlueStorm