Connect Tech 104 Manual De Usuario

Descargar
Página de 26
Connect Tech Xtreme/104-Express User Manual 
 
Revision 0.00 
 
 
11 
 and 
 modes require you to select the appropriate mode 
via software, appropriate wiring and the proper jumper block settings.  Please 
refer to the wiring recommendations (
) and the 
readme.txt
 files found in 
the appropriate directories on the CD.  
Tri-state Operation 
Xtreme/104-Express models offer a power-on tri-state option to ensure glitch-free network 
operation while the system is powering up.  If enabled, the Xtreme/104-Express will tri-state the 
transmitter until the driver opens the port. This operation is configurable for any port configured 
as RS-485, regardless of the RS-485 mode selected.  
 
Jumper J1 controls the power-on tri-state functionality.  Install a jumper on the first location of 
the J1 in order to tri-state Port 1 at power-on.  Install a jumper on the second position for Port 2, 
etc.  The ports will not come out of tri-state until the operating system driver begins transmitting 
on the associated port.  
 
Installing a jumper on J1 will have no effect on ports configured in RS-232 mode.