Connect Tech Xtreme/104-Express User Manual 
 
Revision 0.00 
 
 
RS-232
RS-485
Full Duplex
RS-485
Half Duplex
RS-485
Multi-Drop Slave
Half Duplex Mode 
In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is 
disabled when data is being transmitted. This mode is typically used in either point-to-point 2-
wire connections OR in multi-drop 2-wire bus connections.  This mode requires software setup 
in 
Control Panel – System – Hardware – Device Manager – Ports – CTI Xtreme/104 PCI Express UART Serial 
Port. 
  
Multi-drop Mode 
In this mode the TxD+/- line driver is enabled only when data is transmitted and RxD+/- is 
enabled all the time.  This mode is typically used in multi-drop 4-wire connections.  This mode 
requires software setup in 
Control Panel – System Properties – Hardware – Device Manager – Ports – CTI 
Xtreme/104 PCI Express UART Serial Port
.   
Line Bias/Termination 
The RS-422/485 transceivers can be configured to terminate and produce a line level mark 
condition on the receiver, and/or terminate the transmitter. These options are enabled through 
on-board jumper selectable resistors.  These options are typically used in multi-drop 4-wire or 
half duplex 2-wire connections.  
 
Jumper Block Settings 
The following jumper block diagram depicts typical settings on an interface-selectable 
Xtreme/104-Express. (See 
 for location of jumper blocks.) 
 
 
Figure 2: Jumper Block Diagrams 
 
 
NOTE: You must configure your jumper block settings before installing the 
Xtreme/104-Express into your system. 
 
 
 
 
 
RS-485 Selection
TXD Control
RXD Control
RXD +/- Termination/Bias
RXD +/- Termination/Bias
TXD +/- Termination
Jumper Block Summary