Test Voltages
250 V, 500 V, 1000 V
Accuracy
+20 %, -0 %
Nominal Current
1 mA
Number of measurements
5,000
Circuitry Protection
test inhibited if
≥
30 V ac or dc at inputs
Lo
Ω
Display Range
40.00
Ω
Measurement Range
0.10
Ω
to 40.00
Ω
Accuracy
2 % + 2 counts
Resolution
0.01
Ω
Analog Bar Graph
0 to 100
Ω
Open Circuit Voltage
6 V typical
Short Circuit Current
200 mA minimum, (0.2 to 2.0
Ω
for >20%
battery capacity remaining).
Test Leads Zero
2
Ω
Number of measurements
5,000
Circuitry Protection
test inhibited if
≥
30 V ac or dc at inputs