6500 Disk Array User’s Guide
21020690 B
Chapter 2   Installation
 
Installation Procedure
Page 2 - 3
Installation 
Procedure
Install the 6500 disk array as follows:
Step 1.
Move Array to
Operation Site
Move the array to its intended place of operation. Verify that power and 
communication cables will be accessible, and that the array will be installed in 
a properly ventilated, climate-controlled environment with adequate work 
space around the unit.
Step 2.
Mount
Enclosure
The standard array enclosure is shipped from the factory ready for 
placement on a desktop. Attach the supplied rubber feet to the bottom of 
the enclosure, and position the unit properly on a desk or other work 
surface. 
If you have ordered the rack-mount option, attach the kit to the enclosure 
as described in the instructions included with the rack-mount kit. 
Step 3.
Attach SCSI
Cable
Connect one end of the host-to-array SCSI cable to the host system, and the 
other end to one of the SCSI-P connectors on the rear panel of the array. To 
ensure a secure connection, attach the cable connectors to both the host and the 
array using the small thumbscrews on each connector.
Step 4.
Terminate
SCSI Bus, if
Necessary
If the array is located at the end of the SCSI bus, or if the array is the only 
peripheral device on the bus, install a termination pack (see the figure below.) 
The termination pack will be either single-ended or differential, depending on 
the type of array you are installing. Attach the appropriate termination pack to 
the open SCSI-P connector on the rear panel of the array enclosure. 
Figure 6 SCSI-P Termination Pack