6500 Disk Array User’s Guide
 Chapter 2   Installation
Page 2 - 4 
Installation Procedure 
Step 5.
Set Array
Input Voltage
Switch
Before you connect the array’s power cord to an AC outlet, you must set the 
array power supply’s input voltage selection switch to the proper position: the 
“115” setting for 100-120 VAC, or the “230” setting for 200-240 VAC. 
The power supply’s input voltage selection switch is located between the two 
power cord connectors on the rear panel of the array.
Caution
If the input voltage selection switch is not in the correct position, 
the array power supply will be damaged when power is applied. 
Step 6.
Attach Power
Cord
First, verify that the array power ON/OFF switch on the rear panel of the 
enclosure is in the OFF position. Then plug the power cord into the appropriate 
connector on the rear panel of the array. Plug the other end of the power cable 
into the power source.
Caution
The standard power cord provided with the array is for use in the 
United States and Canada. If necessary, replace the power cord 
with one that meets local safety and electrical standards.
Step 7.
Power Up the
Array
Move the power switch on the rear panel of the array enclosure to the ON 
position. 
Step 8.
Check Array
Status
Observe the display/operation panel for the following start-up displays and 
status indications. 
Drive Status
At array reset or power-up, the display/operation panel will cycle through a 
series of displays that show the status of each drive in the array. 
Drives in the array are numbered from right to left, with drive number 1 
representing the parity drive and drives 2-9 representing the eight data drives.
9 8 7 6 - 5 4 3 2 - 1
(Drive 1 = Parity Drive)