Ciprico 6500 Manual De Usuario

Descargar
Página de 92
21020690 B
6500 Disk Array User’s Guide
 Chapter 4   Maintenance, Troubleshooting & Hardware Replacement
Page 4 - 8 
Failure Detection and Troubleshoot-ing Guidelines 
To choose the Continue response to a BIST error, press the left arrow key. 
To choose the Loop response to a BIST error, press the right arrow key.
When your option, either 
/223 or &217, is displayed, press SELECT to 
implement that option. 
/223 indicates that the array will repeat that particular 
test if SELECT is pressed. 
&217 skips the failed test and continues with the 
other BIST tests when you press SELECT. 
Handling
If you see this
Check or replace this
6&6, %86 ,6 +(/'
:$,7,1*
Check SCSI bus termination (single-ended arrays 
only). Terminator may not be present, may be 
broken, or the wrong kind.
Disconnect the array SCSI cable from Host and 
reset the array. If BIST now passes, the problem 
lies in the host system SCSI interface. Check the 
host SCSI adapter.
8 TGST
(RROR  
Meaning: External SCSI bus error.
Verify Termpower. Check that the TPR jumper is 
installed on the array controller board.
Replace the array controller board.
Note
If a differential controller board is unterminated, 
the BIST will complete without reporting the 
unterminated condition. During subsequent 
operation, various errors, apparently not related to 
the termination, will occur. In the event of 
unspecified error conditions, first verify that the 
differential termination is in place.
TGST NCMG!
(5525 XX XX
Replace array controller board.
Table 4: BIST Troubleshooting