6500 Disk Array User’s Guide
21020690 B
Chapter 4   Maintenance, Troubleshooting & Hardware Replacement
 
Failure Detection and Troubleshoot-ing Guidelines
Page 4 - 9
Drive Test
Failures
When the Built-In Self-Test (BIST) described previously has finished, a 
firmware-based drive test is executed that tests the integrity and functionality 
of each drive channel, including the capacity to rebuild and generate parity.
If a drive fails when tested, the drive is first shown on the display as 
6 (spinning 
up); other drives that pass the drive test are shown as 
* (good). In the following 
example, drive 3 is shown failing the drive test.
When the drive test times out, drives that pass the drive test are shown as 
5 and 
the failed drive is shown as 
) (drive 3 in the example).
Note
If multiple drives fail, the array will display a message similar to 
this message:
Disk Drive
Failures
The array will continue to function if one disk drive fails. 
Caution
When a disk fails, it should be replaced and a rebuild should be 
performed as soon as possible. See disk replacement and rebuild 
instructions later in this chapter.
Indicators
Display/operation panel shows an 
) as status for the drive that has failed
Audible alarm sounds (if enabled)
Handling
If you see this
Check or replace this
21 /,1(
555555)55
Meaning: Drive 3 in the array 
has failed
The order of the drives in the status display is:
      9876_5432_1
with 1 being the rightmost drive in the unit. 
The LED for the failed drive will be out.
Replace failed drive and rebuild.
Table 5: Disk Failures