Getting Started 
Conduct Length Measurement 
 
You can conduct length measurement by using transmissive 
sensor (default setting) for gap label roll or reflective sensor for 
I-Mark media roll. 
 
Please refer to the Programming Reference for changing 
the sensor from transmissve to reflective, if the I-Mark media 
roll is used. 
 
(1)  Open the media compartment cover, the LED1 and LED3 
will light up orange and green respectively, and then start 
flashing after10 seconds.   
 
(2)  Load the media roll. 
 
(3)  Press the FEED button and release it.   
 
(4) Close the media compartment cover, the LED3 flashes 
green 3 times. The MP3200(BT) will feed four labels to 
execute length measurement. After the length measurement 
is completed, the MP3200(BT) will be ready in the next 
printing position and the LED1 of MP3200(BT) will flash 
green(red) at 2 seconds intervals. 
 
(5)  The MP3200(BT) is ready for page mode operation. 
 
 
If the length measurement is failed or executed without setting 
the correct media roll, the MP3200(BT) will issue a paper jam 
error. Please conduct length measurement once again. On 
condition that the length measurement is done successfully, the 
value will be stored into the flash memory. When you load the 
same media roll next time, the MP3200(BT) will perform 
top-of-form by feeding one label or one measured length of the 
receipt paper right after you close the media compartment cover 
in power-on state. 
 
The MP3200(BT) will also feed one label or one measured 
length of the receipt paper while pressing the FEED button. 
However, if you load a different media roll, you will have to 
re-conduct length measurement. 
 
Revert to Standard Mode 
 
The printing mode will be switched to page mode after the length 
measurement is completed. If you would like to revert it to 
standard mode, please follow the steps indicated below : 
 
(1)  Open the media compartment cover, the LED1 and LED3 
will light up orange and green respectively, and then start 
flashing after10 seconds. 
 
MP3200 User’s Guide