Carrier Access Network Device Axxius 800 Manual De Usuario

Descargar
Página de 568
Axxius 800 - Release 2.2
5-59
CLI Commands
exit
exit
Use the exit command to log out of the Command Line Interface (CLI). 
Syntax:
exit
Example:
> exit
Logging out of Carrier Access - Axxius Product Line
install
install (slot) router
The Axxius 800 Controller card automatically creates a backup of the configuration of any 
router cards in their respective slot. If a router card is removed and replaced with a another card 
(of the same type) the backup of the configuration from the first occupying card is loaded onto 
the replacing card. This command will stop this function and the replacing router card will retain 
its configuration. 
Syntax:
install {number} {cmg|router|tsr}
Example:
install 5 router
{number}
The slot number (1-8) of the card to download the software file to. 
{cmg|router|tsr}
The router type. Note: Only the TSR is supported in the this release.
To replace a router card in slot 5 and retain its loaded configuration file:
1. Remove current router card in slot 5 of the Axxius system.
2. With the CLI command enter:
   > install 5 router
   ok
3. When an "ok" is displayed the replacement router card may be inserted into 
slot 5.