S e c t i o n   7
7  OPERATION
This section explains how to enter functions and 
settings directly on the Optipay™ CC A-66 Coin 
Changer using its various operating controls (e.g., 
the front panel Keyboard and the DIP Switch 
Block), rather than using the additional program-
ming tool accessories.
Vending Change by Using the 
Keyboard or Emptying the Tube 
Cassette
Coins can be either vended from the change tubes 
individually if a coin acceptance test is desired, or 
consecutively when the tubes need to be com-
pletely emptied (e.g., before transit, for repairs, or 
in case of an inventory).
Membrane inventory keys 
 and   apply 
to the "left", "middle left", "middle right", and 
"right" coin tubes respectively. 
To vend tube coins individually, simply press the 
corresponding 
 and   key. One coin 
will pay out each time the specific key is pressed.
To vend several tube coins:
1. Hold down the desired 
 or   mem-
brane key for approximately five seconds.
The corresponding tube will automatically 
empty without having to press the respective 
key again.
2. Now, press any other key.
The coins will stop dispensing if not already 
completely emptied.
Emptying the Change Tubes to a 
Certain Fill Level
If a “float” level is configured, the change tubes 
can be emptied to the tube counter’s set float level 
value.
 Emptying the change tubes to the set float level:
1. Press the Plus 
 key.
An audible signal will sound and the Green 
LED will begin flashing indicating that the 
Coin Changer is no longer in a standard oper-
ating mode and has now entered the filling 
level mode.
2. Hold down any key, for approximately five 
seconds (the Green LED illuminates).
All tubes will automatically empty to the 
preconfigured float level. Afterwards, two 
audible signals will sound and the Green LED 
will light constantly indicating that the Coin 
Changer is no longer in the filling level mode, 
and has returned to the operating mode.
Validator Change Filling 
After an inventory or repair the tube cassette’s four 
change tubes can be refilled with relevant coin 
types through the Coin Validator using the key-
board.
If the Coin Changer is configured so the 
inventory keys are disabled, these 
membrane keys will not be active. The 
device is either configured so the keyboard 
can be enabled by the Vending Machine’s 
control system, or so the keyboard must 
be initially activated by one of the various 
configuration tools (see section 11 
"Configuration").
If the Coin Changer is configured so the 
inventory keys are disabled, these 
membrane keys will not be active. The 
device is either configured so the keyboard 
can be enabled by the Vending Machine’s 
control system, or so the keyboard must 
be initially activated by one of the various 
configuration tools (see section 11 
"Configuration").
In many cases the Vending Machine’s 
controls will offer a filling function. In this 
case they should be used, because the 
control unit might not accept the filling level 
capacity of the Coin Changer.
If the Cash Box contains coins, it must be 
emptied, otherwise new coins directed to 
the Cash Box will not be counted.