Agilent Technologies Water Heater E4350B Manual De Usuario

Descargar
Página de 129
Language Dictionary    71
Table 7-3.  Agilent SAS Programming Parameters (in Fixed Mode)
Parameter
Agilent E4350B
Agilent E4351B
CURR[:LEV] MAX and
8.16 A
4.08 A
CURR[:LEV]:TRIG MAX
8.16 A
4.08 A
CURR:PROT[:LEV]: MAX
10 A
5 A
(Programming range is 0 to MAX)
*RST 
Current Value
0.096 A
0.048 A
*RST Current Protect Value
MAX for both models
OUTP:PROT:DEL
*RST Value
0 to 32.767 s (MAX) both models
200 ms both models
VOLT[:LEV] MAX and
61.50 V
123.0 V
VOLT[:LEV]:TRIG MAX
61.50 V
123.0 V
(Programming range is 0 to MAX)
*RST 
Voltage Value
0 V for both models
VOLT:PROT MAX
73.0 V
140.0 V
(Programming range is 0 to MAX)
*RST 
OVP value
73.0 V
140.0 V
 
 
Calibration Commands
 
 
 
 
 
 
Display Subsystem
 
 
This subsystem controls the state and output of the alphanumeric portion of the display.
 
 DISP
 
 
Enables or disables the display.  When disabled, the display characters are blank.  The annunciators are not affected by this
command.
 
Command Syntax
DISPlay[:WINDow][:STATe] <bool>
 
Parameters
 0 | 1 | OFF | ON
 
*RST Value
ON
 
Examples
DISP ON     DISPLAY:STATE ON
 
Query Syntax
DISPlay[:WINDow][STATe]?
 
Returned Parameters
<NR1> or 1
 
Related Commands
DISP:MODE    DISP:TEXT    *RST
 
 DISP:MODE
 
 
Switches the display between its normal metering mode and a mode in which it displays text sent by the user.
 
Command Syntax
DISPlay[:WINDow]:MODE <CRD>
 
Parameters
NORMal | TEXT
 
*RST Value
NORM
 
Examples
DISP:MODE NORM      DISPLAY:MODE NORMAL
 
Query Syntax
DISPlay[:WINDow]:MODE?
 
Returned Parameters
<CRD>   NORMAL or TEXT
 
Related Commands
DISP    DISP:TEXT    *RST