Agilent Technologies Water Heater E4350B Manual De Usuario

Descargar
Página de 129
74    Language Dictionary
MEM:TABL:CURR:POIN?
MEM:TABL:VOLT:POIN?
These commands return the number of current or voltage points in  the active table.
 
Query Syntax
MEMory:TABLe:CURRent[:MAGnitude]:POINts?
 
MEMory:TABLe:VOLTage[:MAGnitude]:POINts?
 
Returned Parameters
<NRI> (number of points)
 
Examples
MEM:TABL:CURR:POIN?
 
MEM:TABL:VOLT:POIN?
 
Related Commands
MEM:TABL:VOLT
MEM:TABL:CURR
MEM:TABL:CAT?
This command returns the names of all user-defined table.
 
Query Syntax
MEMory:TABLe:CATalog?
 
Returned Parameters
<STR> (all table names separated by commas)
Examples
MEM:TABL:CAT?
 
“Table1”, “Table2”,”Table3”,” “ (“ “ = end of list)
 
Output Subsystem
 
 
Output commands control the Agilent SAS's voltage and current outputs and an optional output relay.
 
Source commands program the actual voltage, current, and protection functions.
 
 
 OUTP
 
 
This command enables or disables the Agilent SAS output.  The state of a disabled output is a condition of zero output
voltage and a model-dependent minimum source current (see Table 7-3).  The query form returns the output state.
 
 
Command Syntax
OUTPut[:STATe] <bool>
 
Parameters
0 | OFF | 1 | ON
 
*RST Value
0
 
Examples
OUTP 1     OUTPUT:STATE ON
 
Query Syntax
OUTPut(:STATe]?
 
Returned Parameters
<NR1>    0 or 1
 
Related Commands
*RST    *RCL    *SAV
 
 
 
OUTP:PROT:CLE
 
 
This command clears any OV (overvoltage), OC (overcurrent ), OT (overtemperature), or RI (remote inhibit) protection
features.  After this command, the output is restored to the state it was in before the protection feature occurred.
 
 
Command Syntax
OUTPut:PROTection:CLEar
 
Parameters
(None)
 
Query Syntax
(None)
 
Examples
OUTP:PROT:CLE     OUTPUT:PROTECTION:CLEAR